Product on sale
HF-R 218 PL-T C EII 220-240V 50 60Hz Hot on Sale
25 people are viewing this right now
20 products sold in last 19 hours
Selling fast! Over 12 people have this in their carts
- Estimated Delivery : Up to 4 business days
- Free Shipping & Returns : On all orders over $200
This Philips HF-R 218 PL- T C dimmable ballast runs a 2 x 18w PL-C or2 x 18w PL-T. This ballast s lamp power can be regulated from 1% to 100%, automatic stop start, automatic restart after lamp replacement, up to 75% reduction in energy consumption and quick programme flicker free start.The Philips HD-f ballasts are commonly used in offices. These units are for use with installations with emergency back up.
Specifications
- General information
-
-
Application Code
EII
Type Version
mk3
Lamp Type
PL-T C
Number of Lamps
2 piece unit
Number of Products on MCB (16A Type B) (Nom)
28
Automatic Restart
Yes
-
- Operating and electrical
-
-
Input Voltage
220 to 240 V
Input Frequency
50 to 60 Hz
Operating Frequency (Max)
100 kHz
Operating Frequency (Min)
40 kHz
Ignition Method
Programmed Start
Crestfactor (Max)
1.7
Power Factor 100% Load (Nom)
0.95
Mains Voltage Performance (AC)
-8%-+6%
Mains Voltage Safety (AC)
-10%-+10%
Earth Leakage Current (Max)
0.5 mA
Inrush Current Width
0.35 ms
Constant Wattage Deviation
-2% +2%
Ballast Factor (Nom)
1.0
Inrush Current Peak (Max)
28 A
Efficiency at full load [%]
87.26 %
-
- Wiring
-
-
Connector Type Input Terminals
Insert
Cable Capacity Output Wires Mutual (Nom)
30 pF
Connector Type Output Terminals
Insert
Connector Type Control Input Terminals
Insert
Wire Striplength
7.5-8.5 mm
Dual Fixture Master Slave
Not applicable  [ Master Slave oper. not applicable]
Control Input Terminal Cross Section
0.50-1.50 mm²
Input Terminal Cross Section
0.50-1.50 mm²
Output Terminal Cross Section
0.50-1.50 mm²
Cable Capacity Output Wires to Earth (Nom)
75 pF
-
- System characteristics
-
-
Rated Ballast-Lamp Power
18 W
- General information
-
Application Code EIIType Version mk3Lamp Type PL-T CNumber of Lamps 2 piece unitNumber of Products on MCB (16A Type B) (Nom) 28Automatic Restart Yes- Operating and electrical
Input Voltage 220 to 240 VInput Frequency 50 to 60 HzOperating Frequency (Max) 100 kHzOperating Frequency (Min) 40 kHzIgnition Method Programmed StartCrestfactor (Max) 1.7Power Factor 100% Load (Nom) 0.95Mains Voltage Performance (AC) -8%-+6%Mains Voltage Safety (AC) -10%-+10%Earth Leakage Current (Max) 0.5 mAInrush Current Width 0.35 msConstant Wattage Deviation -2% +2%Ballast Factor (Nom) 1.0Inrush Current Peak (Max) 28 AEfficiency at full load [%] 87.26 %- Wiring
Connector Type Input Terminals InsertCable Capacity Output Wires Mutual (Nom) 30 pFConnector Type Output Terminals InsertConnector Type Control Input Terminals InsertWire Striplength 7.5-8.5 mmDual Fixture Master Slave Not applicable  [ Master Slave oper. not applicable]Control Input Terminal Cross Section 0.50-1.50 mm²Input Terminal Cross Section 0.50-1.50 mm²Output Terminal Cross Section 0.50-1.50 mm²Cable Capacity Output Wires to Earth (Nom) 75 pF- System characteristics
Rated Ballast-Lamp Power 18 W